DAICEN MEMBRANE-SYSTEMS Ltd.

Daicel Group

For the customers who are considering reducing electricity bills at factories and large-scale facilities

Introduction of E mizu Shower will reduce 20% or more power consumption of air conditioning.

The only pure water sprinkler in Japan, E mizu Shower : Patent pending

A result of installation at a shopping moll: 20% or more was reduced by introduction!

  • Download the trial calculation of economic effect (example)
  • Download the calculation sheet of the effect of installation (example)
Contact number

Membrane Sales Department

  • Tokyo +81 (0)3-6631-3000
Contact form
  • Inquiries
  • Request for information materials

Results of E mizu Shower

Reduction of CO2 in corporation unit is becoming an issue because of revision of the Energy Saving Act, and this product is helping a lot of corporations for their energy saving measures.

A result at a commercial complex

Annual amount of reduction of CO2 emission: 104,603kg. Reduction by 20% or more of the maximum demand!

The lineup of E mizu Shower

The lineup of E mizu Shower which responds to the needs from small number to a large number of outdoor units

Supermarkets, small-scale plants, data centers, etc.: E mizu-200D, E mizu-350, E mizu-600. Shopping malls, large-scale data centers, etc.: E mizu-1000, E mizu-2000, E mizu-3000.  *These are the number of units when continuous sprinkling is performed on 10 horsepower outdoor units with the mist nozzle specification.

Are you troubled with scales?

Comparing the aluminum fins on which sprinkling is continuously performed for a month...

Tap water: Adhesion of scales on aluminum fins is observed. RO water: There is no adhesion of scales, and the surface of aluminum fins does not change from the state a month ago.

Sprinkling pure water which does not cause generation of scales is the unique technology of DAICEN.

The mechanism of air conditioning

When the coolant evaporates, it removes heat from the air, and the air which has become cool air is sent into the room, and the room is cooled down.

In summer, the efficiency of the liquefaction process (compression/ cooling) decreases according to the increase in the ambient temperature, and the power consumption increases.

Therefore...

The method of cooling the heat exchanger by sprinkling tap water was developed.

Adhesion of scales on aluminum fins and corrosion are observed, and the whole air conditioning system has to be replaced...

The E mizu Shower system resolves the problem!

It sprinkles pure water, and the problems of adhesion of scales on aluminum fins and corrosion which occurred with sprinkling on outdoor units are cleared.

Contact number

Membrane Sales Department

  • Tokyo +81 (0)3-6631-3000
Contact form
  • Inquiries
  • Request for information materials

Tokyo Headquarters:
JR Shinagawa East Building 14F 2-18-1, Kounan Shinagawa-ku Tokyo 108-8230
TEL: +81 (0)3-6631-3000 / FAX: +81 (0)3-6631-3007